CBCYS - ALKYD FLOOR AND DECK ENAMELS, 3-A (041790M)
- MSDS: CBCYS
- Manufacturer: PPG INDUSTRIES INC
- Product Name: ALKYD FLOOR AND DECK ENAMELS, 3-A (041790M)
- National Stock Number: 8010-00N065457
Product Identification
Product ID:ALKYD FLOOR AND DECK ENAMELS, 3-A (041790M)
MSDS Date:09/15/1992
FSC:8010
NIIN:00N065457
MSDS Number: CBCYS
Responsible Party
ALLISON PARK, PA 15101
US
Emergency Phone: 340-843-1300
Info Phone: 412-492-5555
Cage: DO542
Contractor
Telephone: 412-492-5555
Cage: DO542
Ingredients
ALUMINUM SILICATE
CAS: 1335-30-4
Fraction By Weight: 10-15%
OSHA PEL N/K
ACGIH TLV: N/K
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 5-10%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
PIGMENTS
Fraction By Weight: 2-5%
OSHA PEL N/K
ACGIH TLV: N/K
SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC
CAS: 64742-88-7
Fraction By Weight: 35-40%
OSHA PEL N/K
ACGIH TLV: N/K
XYLENE (SARA 313) (CERCLA)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 1-2%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM/150STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
FILM FORMERS, RESINS, AND ADDITIVES
Fraction By Weight: 35-40%
OSHA PEL N/K
ACGIH TLV: N/K
THIS PROD CONTAINS TITANIUM
RTECS: 9999999ZZ
DIOXIDE DUST IN LONG-TERM STUDY DEVELOPED LUNG
RTECS: 9999999ZZ
VERY LIMITED. SINCE OVEREXPOSURES ARE NOT EXPECTED,
RTECS: 9999999ZZ
DETERMINE TYPE OF AIRBORNE CONTAMINANTS AGAINST
RTECS: 9999999ZZ
BELOW STATED LIM, & TO REMOVE DECOMP PRODUCTS DURING
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: HARMFUL/FATAL IF
SWALLOWED. EYE: IRRIT. SKIN: MAY CAUSE MOD IRRIT. INHAL: VAP &
SPRAY MIST MAY BE HARMFUL IF INHAL. VAP IRRIT EYES, NOSE & THROAT.
RPTD EXPOS TO HIGH VAP CONCS MAY CAUSE IRRIT OF RESP SYS & PERM
BRAIN & CNS DMG. INTENTIONAL MISUSE BY DELIBERATELY CONC & INHAL
CONTENTS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CAN BE HARMFUL/FATAL. EYE WATERING,
HDCH, NAUS, DIZZ & LOSS OF COORD ARE INDICATIONS THAT SOLVENT
LEVELS ARE TOO HIGH. REDNESS, ITCHING, BURNING SENSATION & VISUAL
DISTURB MAY INDICATE EXCES SIVE EYE CONTACT. DRYNESS, ITCHING,
CRACKING, BURNING, REDNESS & SWELLING ARE CNDTNS ASSOC W/EXCESS
SKIN CONT. (ING 7)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST: DO NOT INDUCE VOMIT. EYE: FLUSH IMMED W/PLENTY OF
WATER FOR AT LEAST 15 MIN. SKIN: FLUSH IMMED W/PLENTY OF WATER,
FOLLOWED BY WASHING W/SOAP & WATER. INHAL: REMOVE TO FRESH AIR.
APPLY ARTF RES P & OTHER SUPPORTIVE MEASURES AS REQUIRED. IF
INGEST, ANY TYPE OF OVEREXP/SYMP OF OVEREXP OCCUR DURING/FOLLOWING
USE OF THIS PROD, CONT POIS CTL CTR, EMER ROOM/MD IMMED. HAVE MSDS
INFO AVAILABLE.
Fire Fighting
Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:1.1%
Extinguishing Media:USE NFPA CLASS B EXTING (CARBON DIOXIDE, DRY
CHEM/UNIVERSAL AQUEOUS FILM FORMING FOAM) DESIGNED TO EXTING NFPA
(SUP DAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFFECTIVE. WATER SPRAY MAY BE USED TO COOL
CLSD CONTRS TO PVNT PRESS (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS, & OPEN FLAMES. CLSD CONTRS MAY EXPLODE
WHEN EXPOS TO EXTREME HEAT. DO NOT APPLY ON (SUP DAT)
Accidental Release
Spill Release Procedures:PROVIDE MAXIMUM VENT. ONLY PERSONNEL EQUIPPED
W/PROPER RESP, SKIN & EYE PROT SHOULD BE PERMITTED IN AREA. REMOVE
ALL SOURCES OF IGNITION. TAKE UP SPILLED MATERIAL W/SAWDUST,
VERMICULITE/OTHER ABSORBEN T MATERIAL & PLACE INTO CONTAINERS FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID LONG TERM & REPEATED CONT. DO
NOT STORE > 120F. STORE LARGE QUANTITIES IN BUILDINGS DESIGNED &
PROTECTED FOR STOR OF NFPA CLASS IB FLAMM LIQS.
Other Precautions:IF MATL IS PART OF MULTIPLE COMPONENT SYS, READ MSDS
FOT OTHER COMPONENT/COMPONENTS BEFORE BLENDING, AS RSLT MIX MAY
HAVE HAZ OF ALL OF ITS PARTS. CONTRS SHOULD BE GROUNDED WHEN
POURING. AVOID FREE FA LL OF LIQS IN EXCESS OF FEW INCHES.
Exposure Controls
Respiratory Protection:OVEREXP TO VAPS MAY BE PREVENTED BY ENSURING
VENT CTLS, VAP EXHAUST/FRESH AIR ENTRY. NIOSH/MSHA APPRVD (TC-23C)
AIR PURIFYING/AIR SUPP (TC-19C) RESPS MAY ALSO REDUCE EXPOS. READ
RESP MFR'S INSTRUCTION S & LITERATURE CAREFULLY TO (ING 10)
Ventilation:PROVIDE GEN DILUTION/LOC EXHAUST VENT IN VOL & PATTERN TO
KEEP CONC OF INGS < LOWEST SUGGESTED EXPOS LIM, LEL (ING 11)
Protective Gloves:NITRILE RUBBER OR NEOPRENE RUBBER.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:IMPERMEABLE APRON. EMERGENCY EYEWASH &
DELUGE SHOWER MEETING ANSI DESIGN CRITERIA .
Work Hygienic Practices:CLEAN OR DISCARD CONTAMINATED COTHING AND
SHOES.
Supplemental Safety and Health
EXTING MEDIA: CLASS IB LIQUID FIRES. FIRE FIGHT PROC: BUILD-UP &
POSSIBLE AUTOIGNITION/EXPLOSION WHEN EXPOSED TO EXTREME HEAT. IF
WATER IS USED, FOG NOZZLES ARE PREFERABLE. EXPLO HAZ: HOT SURFACES.
TO XIC GASES MAY FORM WHEN PRODUCT IS CONTACTED BY FLAME/HOT
SURFACES. HAZ DECOMP PROD: FUMES INCLUDING CARBON MONOXIDE.
Chemical Properties
Boiling Pt:B.P. Text:>277F,>136C
Vapor Pres:2
Vapor Density:HVR/AIR
Spec Gravity:1.0-1.1
Evaporation Rate & Reference:<19 (BUTYL ACETATE=100)
Solubility in Water:0.0%
Appearance and Odor:VISCOUS LIQUID W/AN ODOR CHARACTERISTIC OF THE
SOLVENTS LISTED IN INGS SECTION.
Percent Volatiles by Volume:<56
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG ALKALIES, STRONG MINERAL ACIDS, OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRODUCE HAZ DECOMP PROD WHEN
HEATED. WELDING, BRAZING/FLAME-CUTTING ON SURF COATED W/THIS PROD
MAY PRODUCE (SUP DAT)
Disposal
Waste Disposal Methods:WASTE MATERIAL MUST BE DISPOSED OF IN ACCORDANCE
WITH FEDERAL, STATE, PROVINCIAL, AND LOCAL ENVIRONMENTAL CONTROL
REGULATIONS. EMPTY CONTAINERS SHOULD BE RECYCLED OR DISPOSED OF
THROUGH AN APPROVED WA STE MANAGEMENT FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.